ATDP Range

Category:

The Hi-Force ATDP Range of twin double acting air driven hydrostatic pressure testing pumps offer a choice of 3
models with output pressure capacities ranging from 87 Bar (1260 PSI) to 1489 Bar (21600 PSI). The twin double acting
design offers a much higher displacement volume per stroke than the smaller AHP & AHP2 series, making it ideal for
prefill as well as pressure testing. All models are supplied with a 150mm diameter glycerine filled vibra-gauge
(calibrated on request), inlet airline filter, lubricator and regulator unit, pump start/stop valve and fluid strainer.
Viton and ethylene propylene seals for handling special fluids or chemicals can be factory fitted prior to delivery if
required. Other seal materials are available on request.

  • Air consumption 212 scfm (6m3 / minute)
  • Suitable for use with various fluids including water
  • 150mm dual scale glycerine filled gauge
  • Infinitely variable output pressure and flow
  • Fitted with inlet air filter, regulator & lubricator
  • Optional extras include stainless steel frame work, pneumatic or LCD stroke counter system, onboard chart recorder, pressure isolation valve and wheel mounting

SPECIFICATIONS ATDP Range

MODEL NO.MAX OUTPUT PRESSURE (BAR) AT AIRLINE INPUT PRESSUREFLUID VOLUME DISPLACEMENT PER STROKE (CM3)OUTLET PORT THREADWEIGHT KGDIMENSIONS IN MM
20 PSI 1.38 BAR60 PSI 4.14 BAR100 PSI 6.9 BARLENGTHWIDTHHEIGHT
ATDP63872604342751/2″ NPT96765570700
ATDP1251725178621401/2″ NPT96765570700
ATDP2162988941489791 1/8″-12UNF96765570700

OUTPUT FLOW RATE ATDP Range

HYDRAULIC PRESSUREAPPROXIMATE RATE OF DISCHARGE (LITRES/MIN) AT AIR INPUT PRESSURE 100 PSI (7BAR)
PSIBARATDP63ATDP125ATDP216
0032.216.99.5
10006925.7148.8
200013820.512.38
300020716.210.67.4
400027612.59.46.9
500034588.36.4
60004142.87.36.1
8000552*4.85.5
10000690*34.9
12000828*0.44.3
160001103**3.2
200001379**1.6

Note: * Pressure exceeds pump capacity

    Ask for a free quote